Amongst the numerous new or improved products presented by the gas analysis division of Bühler Technologies GmbH, a Germany based manufacturer of globally available products for gas analysis, are advanced versions of the BÜNOX 2+ range of NOx converters.

To enable the analysis of NOx in emission monitoring systems with highly cost effective infrared analysers NO2 is converted to NO. This takes place in electrically heated ovens in which typically disposable reactor cartridges filled with different catalyst material are inserted.

Bühler now has developed an improved conversion material with higher exchange capacity even at temperatures not exceeding 400°C.

Furthermore, within a research project supported by the BMWi*, a completely new carbon based conversion material has been developed by Bühler. This has been achieved by a special treatment step within the production process of the material. Not only that this new material converts safely at 180°C, it does also not produce CO itself and thus eliminates the need of an additional CO analysis and as additional benefit the consumption of electrical energy is reduced significantly.

Additionally wall mounted NOx converters now enhance the range of the BÜNOX2+ program. These types include versions with 180°C heated gas paths for trace measurement and also unheated units.

An important highlight in the efforts to improve the cost of ownership is the new capacity monitor NOXCal, now part of the standard software of all BÜNOX 2+ units. This allows the operators to determine the exchange point of the converter cartridge in advance and thus contributes to an even more reliable continuous emission monitoring.

For more information please click here.

* the Federal Ministry of Economy and Technology upon a resolution of the German Federal Assembly.

IET 36.3 May

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Labmate Online
FOXA1 protein could be a diagnostic marker for aggressive prostate cancer
Explore more Arrow
Pollution Solutions Online
Next-generation reverse osmosis membranes for more efficient and cost-effective seawater desalination
Explore more Arrow
Petro Online
New test method ASTM D8606 has been officially released
Explore more Arrow
Chromatography Today
Non-invasive flowmeters for real-time monitoring
Explore more Arrow