Fully Automated Mycotoxin Detection in the ppq-Range

Environmental laboratory

Fully Automated Mycotoxin Detection in the ppq-Range

17 Jan, 2017

Published over 9 years ago. See the latest and most current information on Environmental laboratory.

LCTech’s robotic system FREESTYLE ThermELUTE enables with its fully automated sample preparation and direct connection to a HPLC system a sample throughput of more than 500 samples per week. The process is done without any manual working steps from extract to the ready chromatogram.

Manual sample preparation is tedious, laborious, and cost-intensive. In combination with a HPLC system the robotic system FREESTYLE ThermELUTE enables fully automated sample preparation and analysis of the mycotoxins Aflatoxin B1, B2, G1, G2, M1 as well as Ochratoxin A and Zearalenone in all regulated matrices.

When developing this system LCTech, specialist in the area of automated sample preparation, has followed the approach of miniaturizing the sample preparation process. Consequently the ThermELUTE is processing immunoaffinity columns with a size of only 3.5 cm, which in turn considerably reduces the processing time as well as the amount of sample and solvent.

The clean-up step itself is performed via thermal denaturation. After being washed, the loaded immunoaffinity column is heated whereby the bond between antibody and toxin is broken. The eluate of the immunoaffinity column is directly and quantitatively eluted from the SMART column, as sample loop partial filling, into the injection port of the LC unit. After derivatisation of the aflatoxins B1 and G1 the eluate is analysed. At the same time the FREESTYLE ThermELUTE begins to process the next sample. With this parallelisation of the two steps, sample preparation and analysis, the sample throughput can be increased enormously.

Moreover, the sensitivity is also drastically increased, because losses through evaporation or adsorption effects are excluded, the complete eluate is injected, and the adjustment to the HPLC mobile phase is omitted. Without special measures or further processing steps the user is able to always measure within the lower ppt-range of the European limits (ppq-range for Aflatoxin M1), even for baby food and to process its application in conformity to EU regulations.

Latest News

IET 36.3 May

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Labmate Online
MIDAS accelerates protein engineering by replacing microbial cloning with PCR
Explore more Arrow
Pollution Solutions Online
AI-driven in-line inspection improves leak and air pocket detection in water networks
Explore more Arrow
Petro Online
Safer, faster on-site density checks for aviation fuel
Explore more Arrow
Chromatography Today
Affordable liquid chromatography solvent delivery pump
Explore more Arrow