CO2 Transmitters With Insensitive Infrared Measurement Principle

Portable & field testing

CO2 Transmitters With Insensitive Infrared Measurement Principle

15 Jul, 2014

Published over 12 years ago. See the latest and most current information on Portable & field testing.

The new CO2 transmitter series EE850 and EE820 from E+E Elektronik (Austria) allows highly accurate and reliable measurements of CO2 concentrations up to 10,000 ppm. The applied infrared measurement principle (dual wavelength NDIR* procedure) is particularly insensitive to pollution. The transmitter’s autocalibration function automatically compensates for aging effects.

The multi-point CO2 and temperature factory adjustment procedure leads to excellent CO2 measurement accuracy over the entire working temperature range. The measured values are available as either analogue current or voltage outputs. An optional kit facilitates easy configuration and adjustment of the transmitters.

The EE850 CO2 and temperature transmitter for duct mounting is ideal for applications in building management or process control. A mounting flange enables easy installation of the sensing probe directly into the ventilation duct. The CO2 sensing cell is well protected inside the transmitter. For CO2 measurement, a small amount of air flows through the divided probe, into the transmitter housing, and back into the duct. The temperature sensor is located inside the probe. The EE850 offers an additional option for a passive temperature sensor output with a 2-wire connection.

The EE820 CO2 transmitter is designed for particularly demanding applications. The robust, functional housing with a special integrated filter allows for use of the EE820 in polluted environments such as agricultural establishments, stables, incubators, or greenhouses. Excellent temperature compensation means the EE820 can even be used outdoors.

* non-dispersive infrared technology

Latest News

IET 36.5 Sept/Oct 2026

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Labmate Online
WEBINAR: Rethinking PFAS analysis: AOF (ISO EN 18157), EOF & alternative measurement technology in focus of UWWTD
Explore more Arrow
Pollution Solutions Online
Smarter wastewater management helps futureproof distillery operations and protect local watercourses
Explore more Arrow
Petro Online
Improving repeatability in diesel fuel lubricity testing
Explore more Arrow
Chromatography Today
Dr. Anupam Giri joins Chromatography Today as consultant editor to strengthen its technical expertise
Explore more Arrow