Gas Detection

  • Will Your Gas Detection System Keep You Safe When You Restart Operations?

Will Your Gas Detection System Keep You Safe When You Restart Operations?

Jul 15 2020 Read 598 Times

As the Government eases lockdown measures that were introduced to combat Covid-19, many businesses are restarting operations.

A break or a shutdown can present highly significant gas dangers. Your risk assessment must address gas hazards before operations begin.

What are the gas dangers?

  1. 1. Storage areas for toxic and/or flammable gases. This is likely to be a widespread danger because such areas are not always industrial. Swimming pool operators store chlorine, food-makers, pubs and bars use gases in the manufacture and dispensing of beverages.
  2. If gas has leaked during a shut-down, it may endanger property and staff when operations begin again. This could be a problem in areas that weren't a problem before a shutdown but because of the lack of ventilation or air movement, dangerous gas could build up particularly in confined spaces.
  3. 2. Stagnation of organic matter creates toxic or flammable gases. For example, methane and hydrogen sulphide may be generated by organic matter that has begun to degrade or ferment.
  4. 3. Unused materials/chemicals can also be hazardous. For example, anything stored at a specific pressure may have experienced a change in that pressure, and materials stored in sub-optimal conditions (e.g. in terms of ambient temperature, pressure, exposure to light or operation) may now be unfit for purpose or even dangerous.
  5. 4. Re-pressurisation of systems. Many industries – public buildings to oil refineries – use pressurised systems or equipment such as boilers, steam heating systems, autoclaves, pipework, heat exchangers and refrigeration plant. If these are not correctly pressurised, they may explode, leak or cause contact injuries. Any break in operations may have caused or coincided with a change (usually a drop) in pressure.
  6. Some systems contain gases that are inherently toxic/flammable, some gases may be safe in normal process conditions but are now less safe due to changes in pressure or other conditions created by a recent shut-down. In any case, there is a legal duty to maintain pressurised systems, so it makes sense to check the system before re-starting operations, and to re-pressurise the system if required.

What should I do before re-starting operations?

Before restarting operations, a complete risk assessment should be carried out which includes gas hazards.

Pre-entry checks may be required to ensure that it's safe to enter. This can be done using Gastec tubes or a portable gas detector. Once in the environment, you may need a respirator to assist with breathing safely until the air is safe to breathe freely.

If there is a continual gas hazard risk, you should have a gas detection system. Have the gas sensors been calibrated recently? Was the gas detection system shutdown and is the system now communicating properly? Has the system been in alarm, what does that mean? It could be worth having the system serviced to make sure everything is running safely.

Bring in the experts

If you have any questions regarding the operation or safety of your environment when it comes to gas detection, a1-cbiss has a wealth of knowledge gathered over many years from the design, installation and servicing of gas detection equipment. 

For advice and support with gas dangers, contact us.

Reader comments

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.

Post a Comment





Digital Edition

Asian Environmental Technology November 2020

November 2020

In This Edition Business New - Acquisition to combine French expertise for moisture analysis in gas - ASTM International Water Committee developing proposed contaminate monitoring standard...

View all digital editions

Events

Biogas Convention 2020

Dec 08 2020 Virtual event

CISILE 2020 - NEW DATES

Dec 08 2020 Beijing, China

InterAqua 2021

Dec 09 2020 Tokyo, Japan

Asia Pharma Expo/Asia Lab Expo

Jan 09 2021 Online event

View all events