M&C (UK) has developed a special sampling technique for continuous measurement of flue gas from DENOX (SCR) plants where NH3 or Urea is added to reduce NOx. This new sampling technique has also proved beneficial for other processes with problematic salt formation, e.g. glass production and FCC on refineries.

With temperatures of < 300°C, ammonium salts can form from the chemical reaction of free NH3 and SO2/SO3 in the flue gas. This salification blocks up filters and sample lines in a short time.   The special M&C gas sample probe SP2000-H320/S offers a good solution. In order to prevent blockage due to salification, the probe temperature is controlled above 300°C, keeping the salts in the vapour phase.   At the outlet of the probe filter, the gas passes into a glass separator vessel filled with glass balls to extend the surface for salt formation. Inherent moisture and solubility of salts means the resulting solution can be easily pumped away, providing a self-cleaning mechanism.   A range of accessories complement this probe including different probe tube materials, calibration gas management, blow-back and external temperature control.

Latest News

IET 36.3 May

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Labmate Online
MIDAS accelerates protein engineering by replacing microbial cloning with PCR
Explore more Arrow
Pollution Solutions Online
AI-driven in-line inspection improves leak and air pocket detection in water networks
Explore more Arrow
Petro Online
Safer, faster on-site density checks for aviation fuel
Explore more Arrow
Chromatography Today
Affordable liquid chromatography solvent delivery pump
Explore more Arrow