Water/wastewater
Published over 13 years ago. See the latest and most current information on Water/wastewater.
The RVL series meter from Badger Meter Europa (Germany) utilises vortex-shedding technology to provide a repeatable flow measurement accurate to 1% of full scale.
The meter has no moving parts, and any potential for fluid contamination is eliminated by the meter's corrosion-resistant all plastic construction. The meter includes a compact 2-wire (4-20mA) or 3-wire (0-5 VDC or pulse) transmitter, contained within a conveniently replaceable plug-in electronics module. All electronics are housed in a corrosion-resistant enclosure.
Unlike meters containing metal or moving parts, the RVL is perfect for aggressive or easily contaminated fluids. Applications range from ultrapure water to highly corrosive chemicals and slurries. Units may be recalibrated and the meter output span reprogrammed in the field. RVL meters are available in the following materials of construction: CPVC, PVC, PVDF and Polypropylene (PP).
IET 36.3 May