  • 3,500 Samples per Year Throughput with New Automated Sample Preparation System for Dioxin Analysis

3,500 Samples per Year Throughput with New Automated Sample Preparation System for Dioxin Analysis

Aug 22 2016 Read 1233 Times

Tedious and elaborate sample preparation makes the sample processing time and cost-intensive. When developing its new system for automated sample preparation in dioxin and PCB analysis LCTech (Germany) focused on shortening the process time, increasing the flexibility of the system, allowing easy handling, and achieving lower costs per sample.

With the system DEXTech Plus, LCTech as the specialist for automated sample preparation succeeded in reducing the processing time to only 35 minutes depending on the sample including conditioning and fractionation. This allows to process up to 3,500 samples per year with only one system. 4 systems in parallel achieve a sample throughput of up to 14,000 samples per year, making the system a perfect solution also for high throughput laboratories.

The 3 column system can be equipped with different ready-to-use columns depending on the analysed matrix or the requested fractions. Insertion of the columns is very simple: The columns are clicked into the system in seconds, without any tools and without screwing. Afterwards they are electrically locked (patented system).

The method set-up is done via touch-screen, where the parameters can be configured freely or pre-stored default methods can be selected.

After the sample vial has been placed into the system, the sample will be quantitatively loaded into the sample loop by the syringe pump. During the whole process the sample doesn’t come in contact with the syringe pump at any time. Due to that, as well as for the systemic rinsing of the device and the exchange of the columns, cross-contamination is reliably avoided.

Various safety features like leakage sensor, overpressure control, and waste level sensor ensure the safety of the users. The locking of the columns is only possible, if the door is closed and the system operates entirely in the low voltage range. An extractor hood is not required.

DEXTech Plus provides an integrated USB-port for reporting and documentation and is compliant with the EPA method and European regulations.

Reader comments

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.

Post a Comment




Digital Edition

International Environmental Technology Buyers Directory 2019

August 2019

A Comprehensive Bibliography of Who’s Who in Environmental Analysis & Monitoring This guide has been produced as a reference of manufacturers and suppliers with their full contact details. The c...

View all digital editions

Events

World Water Week 2019

Aug 25 2019 Stockholm, Sweden

Sensor China

Sep 02 2019 Shanghai, China

Aquatech Mexico

Sep 03 2019 Mexico City, Mexico

ICEF

Sep 04 2019 Gwangju, South Korea

NSC Congress & Expo

Sep 06 2019 San Diego, CA, USA

View all events