Monitoring of H 2 S, NH 3, Benzene, Toluene, Ethylbenzene, Xylene and Dimethylethylamine  

Air monitoring

Monitoring of H 2 S, NH 3, Benzene, Toluene, Ethylbenzene, Xylene and Dimethylethylamine  

14 May, 2010

Published over 16 years ago. See the latest and most current information on Air monitoring.

A new integrative cryogenic air sampler (patent application number 08/00669), able to overcome many of the limitations in current volatile organic compounds and methodologies odour sampling available from Labaqua (Spain). The sample is spontaneously collected in a universal way at 15 mL/min, selectively dried (reaching up to 95% of moisture removal) and stored under cryogenic conditions. The sample is Collected spontaneously in a universal way at 15 mL / min, selectively dried (Reaching up to 95% of moisture removal) and stored under cryogenic conditions.

The sampler performance was tested under time weighted average (TWA) conditions, sampling 100 L of air over 5 days for determination of NH 3 , H 2 S, and benzene, toluene, ethylbenzene and xylenes (BTEX) in the ppm v range. The sampler performance Was tested under time weighted average (TWA) Conditions, sampling 100 L of air over five days for determination of NH 3, H 2 S, and benzene, toluene, Ethylbenzene and xylene (BTEX) in the ppm v range. Recovery was 100% (statistically) for all compounds, with a concentration factor of 5.5. Was Recovery 100% (Statistically) for all compounds, with a concentration factor of 5.5. Furthermore, an in-field evaluation was done by monitoring the TWA inmission levels of BTEX and dimethylethylamine (ppb v range) in an urban area with the developed technology and comparing the results with those monitored with a commercial graphitised charcoal diffusive sampler. Furthermore, skilled an in-field evaluation Was done by monitoring the TWA inmission dimethylethylamine Levels of BTEX and (v ppb range) in an urban area with the Developer technology and Comparing the results with a commercial Those graphitised Monitor with diffusive charcoal sampler. The results obtained showed a good statistical agreement between the two techniques. The Obtained results show to good statistical agreement Between the two techniques.

Latest News

IET 36.3 May

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Labmate Online
GLP-1 obesity drugs linked to clinically relevant blood pressure reductions
Explore more Arrow
Pollution Solutions Online
DNV introduces new framework for measuring onboard carbon capture performance
Explore more Arrow
Petro Online
ABB enables thermal mass flow measurement in safety-critical applications with SIL 2 certification
Explore more Arrow
Chromatography Today
Affordable liquid chromatography solvent delivery pump
Explore more Arrow