Automated sample clean-up in PCB and dioxin analysis for samples hardening at room temperature

Jan 22 2019 Read 846 Times

LC Tech’s DEXTech Heat automated system is especially designed to clean up samples that need to remain melted in PCB and dioxin analysis by maintaining the sample’s liquid state with three heating zones - from sample vial to the first column.

In PCB and dioxin analysis, there are an increasing amount of samples that harden at room temperature and thus generate challenges for automated clean-up. LCTech GmbH, the specialist for automated sample preparation, has launched a new system on the market that automatically processes these samples without the need for additional tools or manual handling.

DEXTech Heat, which is based on the unique technology and functionality of LC Tech’s established DEXTech Pure system, processes even the difficult samples such as stearin or PFADs automatically, without clogging and thus enabling reliable and accurate results.

Integrated heating zones heat up all components of the system that are needed for processing the sample and to maintain the sample as a liquid throughout the clean-up process – from sample vial to loading onto the first column. This prevents clogging of the first clean-up column. In addition, the homogeneous consistency of the sample ensures a better distribution of the quantification standard and thus better recoveries.

The temperature of the three heating zones can be set individually via a central control unit.

Like LCTech’s well proven DEXTech Pure, DEXTech Heat separates PCBs and dioxins in one fraction each via a 3-column set-up based on aluminium oxide. The subsequent measurement can be performed for dioxins and PCBs in one GC-MS run each. Default methods in compliance with current regulations are already stored in the system. In case the user only analyses PCBs, an additional shortened method is available that saves time, solvents and costs.

Parallel to the fractionation, offline heating of the next sample is possible which saves the user further time. In addition, the system can also be used without heating for ordinary samples that do not harden at room temperature at any time. Once the system has started, no further manual action is required.

The system’s permanent automated rinsing feature and exchangeable columns ensure that cross-contamination is reliably avoided at any time.

DEXTech Heat conforms to European regulatory requirements as we as those of the USEPA. as does the rest of the DEXTech range.

Reader comments

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.

Post a Comment




Digital Edition

International Environmental Technology Buyers Directory 2019

August 2019

A Comprehensive Bibliography of Who’s Who in Environmental Analysis & Monitoring This guide has been produced as a reference of manufacturers and suppliers with their full contact details. The c...

View all digital editions

Events

World Water Week 2019

Aug 25 2019 Stockholm, Sweden

Sensor China

Sep 02 2019 Shanghai, China

Aquatech Mexico

Sep 03 2019 Mexico City, Mexico

ICEF

Sep 04 2019 Gwangju, South Korea

NSC Congress & Expo

Sep 06 2019 San Diego, CA, USA

View all events