The 900 Series multi-parameter water quality monitor/controller from Myron L® Company does the work of seven separate instruments and is simple to operate and install. Users can easily monitor and control several vital water/wastewater parameters with the same level of precision that Myron L are renowned for. A user-friendly LCD touchscreen graphical user interface and pluggable terminal blocks make installation and configuration a quick and simple job.

Operators can get a full, real-time picture of water quality thanks to continuous readings from up to seven different inputs:  pre-amplified pH/ORP, flexible 0-20/4-20 mA, RTD temperature, flow/pulse, BNC pH/ORP and tow for conductivity/resistivity/TDS/salinity; % rejection as a derived value is optionally available. Conductivity/TDS measurements can be selected from one of three pre-programmed solution modes: potassium chloride (KCl), sodium chloride (NaCl), or Myron L’s own 442 Natural Water™ Standard, or a “User” solution mode based on a known solution can be programmed to maximise precision. 

Temperature compensation is set automatically at 25°C; this can be deactivated by the operator if necessary. The 900 Series’ pH/ORP input channel operates with Myron L pre-amplified pH and ORP sensors. These sensors feature precision circuitry that enhances accuracy and allows sensor application over further distances. The device’s 0-20/4-20 mA input enables operator-defined 0 to full scale values and units of measurement for a wide array of different types of sensors. Electronic or wet calibration is a simple and fast operation.

End-users can activate control equipment and audible signals automatically and continuously report and record solution data with flexible outputs. This instrument includes up to 3 relays, 2 remote alarms, a 0-20/4-20 mA signal, a 0-5/0-10 VDC signal and a RS-485 ASCII serial signal. Relay outputs to all operator-supplied control equipment needing up to 250V each and can trigger on any input parameter. The 0-20/4-20 mA output can transmit a signal for any input parameter. 0-5/0-10 VDC can be scaled to optimise resolution and can output to a recorder, PLC, SCADA system, etc. 0-1 VDC is possible with an optional resistor. 


Digital Edition

IET 34.1 Jan 2024

January 2024

In This Edition Water/Wastewater - Continuous remote water quality monitoring networks Environmental Laboratory - The Important Role of ICP-MS in Understanding the Toxicological Link Be...

View all digital editions

Events

PITTCON 2024

Feb 24 2024 San Diego, CA, USA

Water Today's Water Expo 2024

Feb 28 2024 Chennai, India

Asia Pharma Expo/Asia Lab Expo

Feb 29 2024 Dhaka, Bangladesh

Nepal Lab

Feb 29 2024 Kathmandu, Nepal

ChemTech World Expo 2024

Mar 04 2024 Mumbai, India

View all events