Industrial process operator that have environmental permit, should be aware of the requirement to ensure that any continuous emissions monitoring systems (CEMs) that are installed at emission points to air are functioning correctly. In 2004 BS EN 14181 was introduced to provide formal quality assurance procedures to be applied to CEMs on all processes falling under the Waste Incineration (WID) and Large Combustion Plant (LCPD) Directives.

The principles of BS EN 14181 are relatively simple in that suitable monitoring equipment is installed; it is set up correctly, calibrated effectively and monitored over time to ensure the derived calibration function maintains its validity and suitable checks are made. The outcome of this is to increase both the accuracy and precision of the installed instrument, thus increasing the confidence in the results it reports and ultimately reducing the potential requirement for additional specialist monitoring to verify the performance of the process.

Despite this relatively simple overview the processes involved in the execution of BS EN 14181 are quite complex and vary depending on the installation, the instrumentation and the industrial process operator. Over the past few years, stack emissions monitoring organisations performing EN 14181 work have been doing so outside the scope of ISO/IEC 17025 accreditation, and both industry and the Environment Agency have seen very variable quality in the way this work has been implemented, resulting in some extreme cases whereby a perfectly functional CEM has been condemned as malfunctioning due to basic misunderstandings of both the EN 14181 processes and the installation that was being monitored.

IET 36.2 Mar/Apr 2026

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Labmate Online
Electronic pipettes advance non-opioid pain research
Explore more Arrow
Pollution Solutions Online
Next-generation reverse osmosis membranes for more efficient and cost-effective seawater desalination
Explore more Arrow
Petro Online
Next-generation quartz crystal moisture analyser line expanded
Explore more Arrow
Chromatography Today
Chromatography and XFEL imaging reveal critical point behind water’s behaviour
Explore more Arrow