  • How to measure phosphorus without using colorimetry or any reagents at all

How to measure phosphorus without using colorimetry or any reagents at all

May 09 2018 Read 746 Times

Compass CPR, from PMA, is a feed forward coagulation control system for wastewater treatment works, but with a difference – Compass CPR characterises organic load AND outputs a phosphorus concentration that is subsequently used as part of the nutrient removal control philosophy - all achieved without the need for chemical reagents nor consumable parts, the system being based on an advanced optical measurement system.

Compass CPR utilises the full UV-Vis spectrum to characterise organic material and other components in wastewater that consume coagulant. Compass CPR is the most comprehensive control system available for ensuring wastewater treatment works can optimise dosing regimes and ensure compliance with both metal and phosphorus discharge consents is possible.

The premise is simple, if you don’t measure the coagulant demand of the incoming water, you’re always going to struggle to optimise dosing to ensure P removal AND comply with your metal consent limits.

Using the basis of co-occurrence, phosphorus can be calculated using statistical analysis combined with some initial spot sampling. If you understand the organics coming into the works and know the associated phosphorus levels, then you can correlate an output to a total phosphorus or orthophosphate concentration. A site that evaluated Compass CPR did just this, and Compass was able to output a phosphorus result with an R2 value of 0.84 which for control purposes has been demonstrated as sufficient.

Coagulant dosing based on incoming phosphorus loading is just one part of the Compass CPR algorithm. If for example the majority of your coagulant demand is from organics and suspended solids, then measuring this is a crucial part to optimising coagulant dosing - without it, you’ll often be over-dosing ‘just in case’ the organic loading is high.

Phosphate colorimetry has been a good approach to coagulant dosing in many sites in the UK that have moved away from flow paced dosing, but it has its issues such as fouling, chemical consumption, maintenance and total cost of ownership (TOTEX). Now there is now a better approach which is; lower operating cost, significantly more comprehensive and quicker to respond to raw wastewater changes.

Reader comments

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.

Post a Comment




Digital Edition

Asian Environmental Technology May 2019

May 2019

In This Editon Business News - Measuring the methane component of GHG emissions - Blackline Safety reports strongest quarter ever with revenue up 64% - Restek and LECO collaborate in worldw...

View all digital editions

Events

SETAC Europe

May 26 2019 Helsinki, Finland

Caspian Power

May 29 2019 Baku, Azerbaijan

ASMS Conference

Jun 02 2019 Atlanta, GA, USA

Aquatech China 2019

Jun 03 2019 Shanghai, China

EAGE Conference & Exhibition 2019

Jun 03 2019 London, UK

View all events