  • New Portable Analyser Biogas and Syngas ETG MCA 100 Syn P

New Portable Analyser Biogas and Syngas ETG MCA 100 Syn P

Nov 06 2017 Read 1798 Times

The new portable analyser Biogas and Syngas ETG MCA 100 Syn P is the ideal solution for the measurement and analysis processes for the Biogas to Syngas and burning due to its robustness , accuracy, reliability , and enhance performance.
Unlike other analysers of the same type ETG MCA 100 Syn P performs the analysis of different compounds such as CO, CO2, CH4 NDIR technology with unique optical IR bench . The concentration of O2 by E.C. as well the CnHm, N2 and Calorific value.

The measurement of the concentration of Hydrogen is made ​​highly reliable thanks to the sensor measurement of Hydrogen based on TCD principle of operation ( thermal conductivity ) ; therefore not used for the measurement of Hydrogen , electrochemical cells or other sensors that could interfere with the measurements of Hydrocarbons. Like the versions biogas analyzer MCA 100 Syn- remote- P is standard on PCs and Smartphones (Android , iOS , Windows , etc. .. ), or via a LAN, as well as USB (Wi -Fi as an option).
ETG brings in its laboratories , specific corrections for the measurement of hydrogen into a mixture containing hydrocarbons ( which is precisely the Syngas ) , so as to obtain a measurement as accurate as possible.
Inside there is a suction pump can be activated or not by software, a valve for regulating the flow with the video indication , an in-line filter for the removal of dust , in addition to the optical bench and the electronics required to operate .
The analyzer saves the data in a directory inside the instrument. Csv , dividing and subdividing the log file for the same in different folders named as the current date of analysis; to download the data , the user only needs to insert a memory stick into the mail panel , select the log file in question ( which will be shown with date and time ) and the system will automatically download the data on the pen drive , removing the original file from the internal memory , avoiding the risk of filling the memory.
The analyser is supplied in an impact-resistant case , with degree of protection IP67.

 

Reader comments

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.

Post a Comment




Digital Edition

International Environmental Technology April 2019

April 2019

In This Edition Business News - New appointment to boost noise and vibration specialists - Restek and LECO collaborate in worldwide supply agreement - Evonik catalyst in the life support sy...

View all digital editions

Events

64th ISA Analysis Division Symposium

May 05 2019 Galveston, TX, USA

Ozwater 2019

May 07 2019 Melbourne, Australia

ENVEX

May 15 2019 Seoul, South Korea

FlowExpo 2019

May 16 2019 Guangzhou, China

AIHce 2019

May 20 2019 Minneapolis, MN, USA

View all events