Safe operation of a Water Treatment Plant (WTP) requires careful monitoring of the water supply influent to the plant, as a guard for any substances entering the treatment works that could negatively impact treated water quality in the distribution system. One aspect of water quality that has recently garnered more attention from authorities and utilities is Natural Organic Matter (NOM), which refers to a group of carbon-based compounds found in natural water systems formed by the decomposition of organic materials and associated metabolic reactions. While NOM itself does not pose a risk to human health, some NOM compounds are known to react with chlorine and chloramines in drinking water treatment to produce disinfection by-products (DBPs) such as Trihalomethanes (THMs) and Haloacetic Acids (HAAs), which are known to be carcinogenic and/or genotoxic (Figure 1). Health Canada, the US Environmental Protection Agency, and the World Health Organization include sections focused on control of DBPs in their Drinking Water Treatment Guidelines.

Preventing the formation of DBPs is a multi-faceted challenge for drinking water utilities, with a variety of strategies being developed for both general treatment and specific plant/source conditions. Each facility and water source are different, therefore no one strategy can be applied across the board, and often utilities are encouraged by their local authority to have a unique monitoring plan developed. Prevention strategies can be generalized into four groups:

•  Optimization of treatment conditions to remove precursor NOM compounds;
• Using a different chemical disinfectant with less tendency to form by-products;
•  Using a non-chemical disinfectant; and/or
•  Removing DBPs prior to distribution.

Since drinking water plants typically maintain a disinfectant residual in the distribution system, use of solely a non-chemical disinfection is often not an option. Similarly, most guidelines specify chlorine or chloramines for disinfection, therefore it can be difficult and costly to switch to a different chemical disinfectant. Removal of DBPs before distribution is often not practical, due to high implementation costs and uncertainty as to whether the DBPs are forming at the plant or in the distribution system through reactions with residual disinfectant. Therefore, the preferred prevention strategy for most utilities is optimization of treatment conditions to remove the precursor NOM compounds.
For utilities beginning to address DBP formation through removal of precursor compounds, it is crucial to gain a full understanding of the NOM present in the source water matrix influent to the plant. This is especially important for sources that experience seasonal/temporal variations, which is common for many surface water systems and some groundwater systems. Traditional parameters for monitoring of source and treated waters include Total Organic Carbon (TOC), Dissolved Organic Carbon (DOC), Ultraviolet Absorbance at 254nm (UV254), and Specific Ultraviolet Absorbance (SUVA) which is a combination of DOC and UV254. These parameters are complimentary to each other, providing different insights into the overall NOM makeup, however they each have shortcomings and individually do not reveal the full picture.
Recently, a new photoelectrochemical oxygen demand (peCOD) method has been developed for fresh water systems. The method provides a bulk measure of the chemical oxygen demand (COD) in source and treated waters, which relates to the oxidation state, or reactivity of the NOM; TOC simply quantifies the amount of carbon but provides no indication as to how the NOM will react with and be affected by treatment. peCOD features a low detection limit (<1 ppm), rapid analysis time (<5 min), and streamlined operation making it an ideal parameter for utilities to implement for source monitoring. ASTM International has published a new method specific to peCOD (D8084-17), and the Canadian Ministry of Environment has also published a method for peCOD in surface waters (E3515). In response to this, Health Canada will be including COD in its upcoming guidance document on NOM in drinking water, with a recommended limit of <5mg/L for treated drinking waters. This value was based of the EU Directive 98/83/EC, which outlines an ‘Oxidizability’ parameter for treated drinking water following the Permanganate Index method.
The peCOD method involves introducing a small aliquot of sample to a microfluidics chamber containing Titanium Dioxide (TiO2). The chamber is then irradiated with a UV lamp, photo-catalyzing an advanced oxidation process via the TiO2 (Figure 2). As the oxidation occurs, charge (Qnet) is generated proportional to the oxygen demand of the organics in the sample (Figure 3). The output of the test is an ‘oxidation profile’, a plot of the output current (IWork) vs. time. The area under this plot is directly proportional to the COD of the sample (Figure 4).
A drinking water utility in Massachusetts has recently adopted the peCOD parameter as part of an effort to predict and control the formation of DBPs. This utility receives source water from a tributary of the Connecticut River, a major watershed providing drinking water for millions of households in the Northeast U.S. states, and sees a great amount of variation in source water quality throughout the year, and even from events such as storms and rapid snowmelt. In early 2017, they implemented peCOD alongside TOC and UV254 in an online monitoring system, with the end goal of using real-time monitoring of these parameters to develop a model for dictating treatment actions, such as pH adjustment and coagulant dosing. The first stage of this project is to establish baseline conditions for each of the parameters, as well as comparing their response to events known to influence NOM. A few excerpts of data from the first year of monitoring are provided in Figure 5.
The four data graphs show peCOD, UV254, and TOC responding to four different storm events in the summer of 2017. There are a few interesting points to note about the responses:
1. In the June 16 – 19 events, it is apparent there is similar trending between UV254 and peCOD (TOC was offline). A large dip was detected by peCOD before the first event spike, which barely registered on UV254 compared to the peak. As this occurred for ~5 hours before the spike, it would be relevant information affecting treatment decisions. Also note, UV254 experienced a sharp false spike in the reading around 10:00 on the 19th, behaviour which causes operators to lose faith in the measurement.
2. In the June 23 – 25 events, peCOD, UV254, and TOC respond very similarly to a short, large spike (<1h) followed by a longer, small spike (>5h). PeCOD and UV254 doubled, and TOC increased by ~50%. This behaviour (short, large spike followed by long, smaller spike) was seen on numerous occasions over the year and could be related to a specific storm size/variety.
3. For July 15 – 17, peCOD detects small variations over a couple days before the event, which barely register on TOC or UV254. When the short event (<1h) occurred, peCOD spiked over 4x the baseline, TOC doubled, and UV254 barely changed. This event may have been related to contamination of a specific compound that TOC and UV254 have difficulty measuring.
4. For August 4 – 6, peCOD and TOC are compared for an event with behaviour similar to the June 23 – 25 events (short spike followed by longer spike). Interesting to note is that the second spike of this event measured higher for peCOD than the first spike, suggesting that peCOD detected an additional fraction of the NOM that TOC was not able to detect.
These examples illustrate support for the value of the peCOD parameter in the application of source water monitoring. The data indicates that peCOD can successfully capture/detect any event detected by UV254 or TOC and suggests that peCOD can capture/detect a greater fraction of the NOM than the other parameters for certain events. The next stage of this project for the Massachusetts Utility is to utilize a THM analyzer alongside the online analyzers monitoring source water, which mimics disinfection to form then measure THM DBPs. The utility will develop correlations and trends for each parameter, as well as combinations of parameters, to actual DBP formation. The implementation of the peCOD parameter has already given the utility a barrier of protection, in that the operators constantly check the value to get an idea of the incoming NOM to the plant. As more data is collected, the operators will continue to establish connections between measured values/behaviour and real plant decisions, improving their operation efficiency leading to reductions in operating cost.  The simplicity and low cost of the peCOD method enables use by operators 24/7 in any environment.

Free to read

This article has been unlocked and is ready to read.

Download


Digital Edition

AET 31.2 Buyers' Guide 2024

February 2024

In This Edition Buyer's Guide Directory - Product Listings by Category - Suppliers Listings (A-Z) Water / Wastewater - Methane Emissions Analysis at Berlin Wastewater Facility - Inter...

View all digital editions

Events

Intersol 2024

Mar 26 2024 Paris, France

FORUM LABO LYON

Mar 27 2024 Lyon, France

UzChemPlast Expo

Apr 03 2024 Tashkent, Uzbekistan

analytica 2024

Apr 09 2024 Munich, Germany

View all events