Lisbon Trial Shows Benefits of In-Pipe Monitoring - Tony Halker

Feb 02 2011

Author: Tony Halker on behalf of Intellitect Water

Free to read

This article has been unlocked and is ready to read.

Download

In January 2010, EPAL commenced a pilot project to monitor water quality in Lisbon’s distribution network using Intellitect Water’s innovative Intellisonde™ in-pipe water quality monitors. The trial sought to assess both the technology and the benefits to be gained from continuous access to water quality data between the treatment plant and the consumer.

Developed to continuously monitor up to 12 parameters within drinking water distribution networks, the Intellisonde™ is a small water quality monitor that can be inserted into pressurised pipes. Intellisondes™ can be supplied with their own GPRS telemetry capability, but in this trial the instruments’ analogue output capability was utilised to interface with an existing telemetry network.

The project enabled an evaluation of logged water quality data and tested the ability of the remote monitoring network to integrate the data into EPAL’s existing network management system. This data was used by EPAL to perform diagnostics and to enable process improvements as part of a proactive approach to network management.

EPAL had previously installed and operated a network of nearly 300 Cellos (wireless dataloggers) and associated software for monitoring flow and pressure values, so it was advantageous to integrate Intellisondes™ into this network monitoring system.

Four Intellisondes™ were deployed strategically in a sub-zone and connected to Cellos. The Cellos have eight channels and the Intellisondes™ were configured to measure seven water quality parameters, with the eighth channel configured to monitor battery life.

The water quality parameters measured were Temperature, pH, Turbidity, Conductivity, Free Chlorine Residual, Free Chlorine + Mono-Chloramines, and ORP (REDOX).

The Intellisondes™ logged at 15 minute intervals with the data sent remotely via the Cellos every 24 hours, because this is the same transmission frequency operated by EPAL’s flow and pressure loggers.

The data collection software was programmed to alarm any water quality events outside defined limits for Free Chlorine and Turbidity and the battery voltage programmed to monitor the battery power decay.

Initial installation of the equipment and calibration were carried out with the support of Intellitect Water. Monthly checks were carried out by the EPAL Team using portable calibration equipment to verify the accuracy of the measurements.

Planned maintenance routines were undertaken after six months to replace the Chlorine Sensors and Reference Electrodes, which had reached the end of their useful life. Initially,

Free to read

This article has been unlocked and is ready to read.

Download


Digital Edition

IET 34.2 March 2024

April 2024

Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...

View all digital editions

Events

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

CleanPower 2024

May 06 2024 Minneapolis, MN, USA

IFAT Munich

May 13 2024 Munich, Germany

REGATEC 2024

May 15 2024 Lund, Sweden

View all events