• Refrigerant Leak Detectors at SENSOR+TEST

Gas Detection

Refrigerant Leak Detectors at SENSOR+TEST

Mar 11 2016

Refrigerant gas leak detection is becoming a high priority for many companies, especially considering the increasing price of refrigerant gas, not to mention emergency service call-out costs to find, detect and repair leaks of hydrofluorocarbons (HFC), chlorofluorocarbons (CFC), hydrochlorofluorocarbons (HCFC), Ammonia or CO2, and the potential for loss of inventory if a major leak renders a system inoperable. Installation of InfraRed Leak Detection Systems (IRLDS) is becoming increasingly important to be able to monitor for leaks in critical areas continuously. Along with the above concerns, depletion of the ozone layer is everyone's responsibility to prevent further damage to the environment.

One of the most difficult areas of sealed system servicing can be trying to find a refrigerant leak. The refrigerant leak may exist within a series of tubing that may be up to hundreds of feet long or in a component that is not readily accessible or may even be, totally concealed. It could be in an operating or safety control such as a pressure switch, an expansion valve in a display case or in the compressor room located far from normal human traffic.

Other sources of fugitive emissions of refrigerant gas are from refrigerant manufacturing plants, refrigerant storage or transfer stations. Area monitoring of these facilities can alert the proper authorities to initiate corrective action.

Typical IRLDS leak monitors either employ detectors mounted at or near expected sources of fugitive emissions wired to a central console or a central sampling station which "pulls" a sample via pneumatics circuits to periodically introduce a representative sample into an analyzer/detector.

Using refrigerant leak detectors at each point poses a maintenance problem for the system operator as the routine maintenance and calibration has to be repeated once per sampling point. Automating the calibration requires additional cost and complexity to the system.

IRLDS detection locates the sensing component at a central location, which can more easily be accessed for maintenance and calibration. Judicious use of flow or pressure sensing on each run of sample tubing can be used to detect filter or tube and filter blockage to make the well-designed sampling type of IRLDS a cost effective means to monitor for refrigeration gas leaks in refrigeration systems.

The Andros 6552, from LumaSense Technologies (Germany), can address many of the needs of the integrator with the basic NDIR bench. Up to three sample points and a dedicated zero channel can be supported directly with the on-board 12 VDC solenoid valve drivers. Additionally a 12 VDC pump can be directly operated by the 6552 or can operate a relay to operate AC pumps when higher flow rates are needed. The 6552 has a differential pressure transducer available for flow measurement as well as an absolute pressure transducer for gas channel compensation and automatic shut off of the pump in case of sample cell overpressure.

Visit LumaSense Technologies at SENSOR+TEST 2016, Hall 1, Stand 1-208. 


Digital Edition

IET 34.1 Jan 2024

January 2024

In This Edition Water/Wastewater - Continuous remote water quality monitoring networks Environmental Laboratory - The Important Role of ICP-MS in Understanding the Toxicological Link Be...

View all digital editions

Events

Water Today's Water Expo 2024

Feb 28 2024 Chennai, India

Asia Pharma Expo/Asia Lab Expo

Feb 29 2024 Dhaka, Bangladesh

Nepal Lab

Feb 29 2024 Kathmandu, Nepal

ChemTech World Expo 2024

Mar 04 2024 Mumbai, India

SIAF Guangzhou

Mar 04 2024 Guanghzou, China

View all events