• Smart S

Gas Detection

Smart S

Feb 15 2018

Designed to meet with the toughest industrial requirements, SMART S-SS line allows monitoring toxic, flammable gases and Oxygen contents for both it depletion and enrichment in harsh environments.

They offer 5 status LEDs and an 8 digits back-lit display for the gas concentration reading to be chosen between LCD or LED display. They feature non-intrusive calibration for an accurate and easy adjustement via Hall-effect switches, which allow to access the detector without opening the instrument and declassifying the area.

SMART S-MS (Marine & SIL) line allows monitoring toxic, flammable gases and Oxygen contents for both it depletion and enrichment in harsh environments. Designed to offer increased resistance to corrosive elements, this range of products is ideal for marine application. SMART S-SS and SMART S-MS offer SIL2 Hardware, SIL3 software approved capability and can detect flammable compounds (%LEL), toxic and refrigerant gases in ppm and Oxygen contents for both its depletion and enrichment. They offer a complete range of sensor heads for all applications: the SMART S-HEAD line has been designed to offer a wide range of alternatives that grant customers the best solution to their requirements.

Pellistor sensors employed for all flammable gas detection, included hydrocarbons, ammonia, hydrogen, fuel and petrol vapours, show an excellent output linearity up to 100% LEL. For aggressive atmospheres, where the Pellistor functionality might be seriously compromised by the presence of inhibitors or poisons, Sensitron proposes a range of industrial grade Infrared sensors: IR sensors are immune from poisoning and this guarantees a higher accuracy and a longer lifetime. For the toxic gas detection, Sensitron has operated a reliable selection among the most performing electrochemical cells to supply units representing the state of the art in toxic gas detection. SMART S-IR is able to offer the hybrid technology (IR+Pell).

The detectors can be housed in alloy or stainless steel enclosures. Output 4-20 mA 3 wires & RS485 Modbus Wide range of sensors and detectable gases Hart modem with 3-relay card (optional), 3 relay output (optional), Certifications: IECEx, ATEX II2G &SIL 2(3), Detection of flammable gases, toxic gases and Oxygen, SIL 2(3) (EN50402, EN61508 part 1-7) IP 65 (optional IP67),Alloy or stainless steel version.


Digital Edition

IET 34.2 March 2024

April 2024

Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...

View all digital editions

Events

Hannover Messe

Apr 22 2024 Hannover, Germany

FORUMESURE

Apr 22 2024 Marrakech, Morroco

Asia Water 2024

Apr 23 2024 Kuala Lumpur, Malaysia

Korea Lab 2024

Apr 23 2024 Kintex, South Korea

Canadian Hydrogen Convention

Apr 23 2024 Edmonton, AB, Canada

View all events