Analysis by Curie-point-pyrolysis Coupled with Gas Chromatography Ms

Environmental laboratory

Analysis by Curie-point-pyrolysis Coupled with Gas Chromatography Ms

18 Apr, 2008

Published over 18 years ago. See the latest and most current information on Environmental laboratory.

Routine analysis does require automation due to the increasing demand for shorter analysis times, higher throughput and cost reduction. The Pyromat by GSG Mess- und Analysengeräte GmbH (Germany) is truly innovative allowing you to load up to 24 samples for unattended analysis.
All parameters such as temperature, pyrolysis time and of course GC conditions, can be defined for each sample, if required.
The Curie-Point-Pyrolyser can be installed or removed fromthe GC in just a fewminutes. In this way you can easily change - reliably and safely - between pyrolysis and liquid injection.
Despite the power of modern analytical instruments techniques of analysis such as gas chromatography and mass spectrometry one of the most important challenges remains that of sample preparation - especially far non-volatile, insoluble materials and chemicals.
Sample preparation can require a lot of time and expertise particularly when dealing with small sample amounts.
Pyrolysis is a well-established method for the analysis of complex non-volatile, chemical materials and provides a time saving alternative. With pyrolysis techniques it is not necessary to performsample preparation. In addition small amounts of sample (micrograms) may be sufficient for an analysis.
The advantage of Curie-Point-Pyrolysis is the use of ferromagnetic material which heats up in a very short time inside a magnetic field to a defined Curie-Point temperature. With increasing temperature the permeability of ferromagnetic materials decreases. At the Curie-Point the relative permeability of the sample carrier falls suddenly and the status changes instantaneously from ferromagnetic to paramagnetic.
Pyrolysis temperature may be controlled by selection of the composition of the sample carrier, e.g. pure iron has a Curie-Point temperature of 770 degrees Celsius and nickel 358 degrees Celsius. Through the selection of different alloy compositions Curie-Point temperatures can be provided from 160 to 1040 degrees Celsius in ca. 15 degree steps.
Following pyrolysis the fragments are transferred by the carrier gas into the gas chromatograph for separation and detection. Applications for Pyroylsis include: Polymers, co-polymers, elastomers, synthetics, rubber, Lacquers, paints, resin, wax, pigments, biological-/geological materials and microbiological assays.

IET 36.2 Mar/Apr 2026

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Labmate Online
Enhanced recirculating chiller range
Explore more Arrow
Pollution Solutions Online
New all-in-one fish silage system for aquaculture and fish processing industries
Explore more Arrow
Petro Online
Free webinar: enhancing accuracy and efficiency in renewable fuel laboratory testing
Explore more Arrow
Chromatography Today
Chromatography and XFEL imaging reveal critical point behind water’s behaviour
Explore more Arrow