A Major Advance in Non-Invasive Flow Measurement

Nov 01 2012 Read 2558 Times

Pulsar Process Measurement (UK) have launched Flow Pulse, a compact and cost-effective pipe flow monitor that promises exceptional repeatability, accuracy and simple installation with no down time. Flow Pulse is perfect for monitoring flow rate in fluid distribution systems, for pump efficiency checks, in process plant or sewage pumping stations.

Flow Pulse (patent pending) is a leap forward in flow measurement and in ease of installation - no need to break into a pipe, or to get any engineering involved, just clamp a small sensor to the outside of a pipe and immediately get a reliable, repeatable flow measurement (tools required = one screwdriver). Virtually no installation costs, no interruption to service, clean and simple.

Flow Pulse uses a novel spread spectrum analysis technique never before used in flow monitoring. It introduces a radical new Digital Signal Processing approach for exceptional repeatability:

Ultrasound is fired through the pipe wall at 90 degrees to the flow via a tangentially mounted high-output ceramic, then refracted at angles across the axis of the flow and subsequently reflected from bubbles, particles and vortices in all directions and at a wide range of frequencies. The wide, refracted, ultrasonic beam maximises the ultrasound energy that could be captured from flowing particles. These multiple reflections are received back into the unit via a second crystal.

The mass of data generated is analysed using Flow Pulse’s Refracted Spread Spectrum Analysis (RSSA) digital signal processing platform to derive flow information. RSSA analyses and integrates the received signals over a wide frequency range, then slices them for real-time analysis and flow rate calculation.

Flow Pulse operates in a flow range from as little as 0.3m/s through to 4m/s, with a minimum particle size of 100µ and concentration of 200ppm or above (the equivalent of hard water).

Pipe material can be rigid plastic, stainless steel, mild steel or cast iron. Corrugated pipe is not an issue and even light corrosion will give a good result. Flow Pulse provides repeatability and accuracy of around ±5%.

 

Read comments0

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.


Digital Edition

Asian Environmental Technology Buyers Guide 2019

March 2019

In This Edition Business News - Endress+Hauser achieves gold status again - Technical training for Chinese distributor - First-hand expertise at the biggest ever analytica Vietnam Water...

View all digital editions

Events

Water Philippines

Mar 20 2019 Pasay City, Philippines

FORUMESURE

Mar 25 2019 Nantes, France

Americana

Mar 26 2019 Montreal, QB., Canada

Intersol 2018

Mar 26 2019 Lille, France

The Water Show Africa 2019

Mar 26 2019 Johannesburg, South Africa

View all events