High-speed GCMS Analysis for Improved Productivity and Reduced Laboratory Costs

Apr 27 2011

Shimadzu (UK) has launched the GCMS-QP2010 Ultra, which provides best-in-class performance for GC-MS analysis. Capable of fast data measurement with sensitivity five times higher than previous models, the GCMS-QP2010 Ultra offers improved applicability for comprehensive two-dimensional GC and ultra-high separation. In addition, it is the first GC-MS system with eco-friendly features for saving consumption of power and carrier gas to minimise laboratory operating costs and environmental impact.

Shimadzu used new, patented mass spectrometry technology called Advanced Scanning Speed Protocol (ASSP™), a firmware protocol that optimises the ion transmission hardware parameters with a highly efficient data collection algorithm, to increase data acquisition speed up to 20,000 u/sec and 100 Hz. ASSP also provides the added benefit of maintaining system sensitivity at elevated scan speeds.

To help increase throughput, the GCMS-QP2010 Ultra features high-speed oven cooling for shorter analysis cycles. Using a double jet cooling system, the GC cools from 350 to 50 degrees Celsius in less than three minutes. The combination of a high-speed GC method and a high-speed cooling oven can reduce the analysis cycle by up to 50 percent.

To further increase lab efficiency, the GCMS-QP2010 Ultra can accept two narrow-bore capillary columns into the MS simultaneously. Its twin-line MS system allows users to switch applications without physically modifying the column installation. Users simply decide which columns are required for analysis and choose the associated injection port.

The GCMS-QP2010 Ultra comes equipped with an Ecology mode that reduces the power consumed in analysis standby mode by 36 percent compared to previous models. Ecology mode eliminates unnecessary power consumption by the GC, MS and PC, and it also decreases the consumption of carrier gas. When used over one year of operation, Ecology mode reduces power consumption by 26 percent and carbon dioxide emissions by about 1.1 tons.


Digital Edition

Chromatography Today - Buyers' Guide 2022

October 2023

In This Edition Modern & Practical Applications - Accelerating ADC Development with Mass Spectrometry - Implementing High-Resolution Ion Mobility into Peptide Mapping Workflows Chromatogr...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

ChemUK 2024

May 15 2024 Birmingham, UK

MSB 2024

May 19 2024 Brno, Czech Republic

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

View all events