If you want to integrate powerful detectors for gas analysis in portable devices, the LRM-284 is of great interest. This miniaturised quad channel detector in current mode from InfraTec impresses with its low power consumption, is extremely resistant to electrical interference and is ideally suited for detecting fast signal changes.

With the TO39 housing it externally resembles its pendant in voltage mode, the LRM-254. When looking inside, the two double-operational amplifiers enabling the current mode first stand out. Since it is a single supply detector, an analyser with low power consumption can be designed – a fact which particularly speaks for the operation of the detector in portable devices.

Additional significant differences between both quad channel detectors are demonstrated when comparing the performance. Signal changes will appear faster with the LRM-284 and thus the responding behaviour is more dynamic. At the same time, the signal voltage generated in the process is considerably higher. Consequently, the circuit design can be simplified and the detector becomes more resilient against disturbances, which makes the solution of the measuring task significantly easier. The higher signal levels also support the easy integration of the detector into measuring modules.

One step ahead of competitors

Other performance parameters also stand out, particularly when one considers existing detectors on the market as a reference. The Field of View (FOV) is approximately twice as large. Consequently, much more infrared radiation impinges on the sensor elements whereby the signal-to-noise ratio improves accordingly. With regard to the specific detectivity, the advantage over other products offered is even larger. The value surpasses previously typical performance parameters by three-fold.

Resilient and powerful

Apart from the advantages, whose origin lies in current mode, the LRM-284 combines all qualities that distinguish a PYROMID® multi channel detector. The aperture of the TO39 housing is (5×5) mm2. A robust central window in the cap made of silicon for example, can even be soldered for complete hermetic sealing.

Inside the detector are the (2×2) mm2 large channel filters, which have an additional cost-saving effect when compared with other detectors of their performance class due to their smaller surface area. They are shielded from mechanical stress or from other stresses of harsh environments. Due to the compact stack design, the channel filters move closer to the pyroelectric elements. This reduced distance and the central window integrated in the detector cap are two of the factors that ensure maximum optical performance and allow the LRM-284 to convince due to its high performance. The thermally compensated detector has been designed primarily for applications of industrial and medical gas sensors.

Read comments0

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.


Digital Edition

International Environmental Technology February 2019

February 2019

In This Edition Business News - Changes on the Endress + Hauser Executive Board - Nivus in full flow - Yokogawa announce appointment of President and Chairman Gas Detection - ATEX app...

View all digital editions

Events

ChemTech World Expo 2019

Feb 20 2019 Mumbai, India

WaterEx World Expo 2019

Feb 20 2019 Mumbai, India

Water Expo 2019

Feb 21 2019 Chennai, India

EUEC 2019

Feb 25 2019 San Diego, CA, USA

Safety at Work. Labour Protection Workwear

Feb 26 2019 Minsk, Belarus

View all events