• AQE 2018 workshop abstract

Air Monitoring

AQE 2018 workshop abstract

Sep 10 2018

Study of the effect of PM size distribution on CEMS response in a large-scale coal CHP plant

Erkki Lamminen, Samuli Pylkkönen, Mikko Moisio, Dekati Ltd.

Continuous emissions monitoring systems (CEMS) are used in power plants to monitor the level of emitted particulate matter from the stack. In order to evaluate which changes affect CEM calibration, it is important to understand the sources of possible changes in PM size distribution inside the stack.

In this study we 1) compared the second by second response of a PM CEM to a non-continuous real-time PM instrument and 2) evaluated the effect of changes in PM size distribution on the CEM response in a large-scale coal CHP plant. To examine the PM size distribution changes, we used the Dekati® High Temperature ELPI®+. The advantages of the High Temperature ELPI®+ include its capability of measuring PM size distribution in real-time, and directly from the high temperature source. The results show very similar trend for mass concentration for CEM and HT-ELPI®+, but also that the number size distribution shape is significantly different before and after a large baghouse cleaning spike.

Dekati Ltd instruments are distributed by Scielutions Ltd (UK). Scielutions Ltd. provides aerosol instruments and measurement services from leading manufacturers


Digital Edition

IET 34.2 March 2024

April 2024

Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...

View all digital editions

Events

Ozwater'23

Apr 30 2024 Melbourne, Australia

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

CleanPower 2024

May 06 2024 Minneapolis, MN, USA

View all events