• Flow Measurement Using Cable Lengths of 800 Metres
    The 500 m dam wall of Bouzey reservoir

Water/Wastewater

Flow Measurement Using Cable Lengths of 800 Metres

Nov 23 2015

Bouzey reservoir is situated on the western rim of the French Vosges close to the city of Épinal. The reservoir has a storage volume of approx. 7 million m3 and since 1882 ensures steady water supply for the "Canal des Vosges".

To dam up the lake a gravity dam with a height of 20 m and a length of more than 500 m was built of traditional brickwork 130 years ago. The dam structure however was calculated wrongly. Due to this, a flood in 1895 caused a breach in the dam resulting in a disaster with many deaths and a great deal of material damage.

The dam was rebuilt and its base was reinforced using rock-fill. Within the dam there are two accessible inspection shafts with a length of approx. 250 m and 700 m. These shafts, among other things, are used to collect and to discharge seepage water. An earthquake in February 2003 has slightly affected the dam again which becomes obvious in growing seepage water infiltration. 

Considering the effects of the past breach in the dam, the operators decided to analyse the consequences by strengthening the seepage water controls in order to forestall possible new threats.

Since the regular inspection of seepage water infiltration particularly in the lower shaft is very time-consuming and can be executed only under difficult physical conditions, it is now planned to install accurate and continuously operating flow meters at the critical points of the dam bottom. Due to the very high humidity prevailing within the inspection shafts, the transmitters are to be installed in a switching cabinet out of the dam body from where they can be connected to a monitoring system via Internet.

Apart from providing comfortable representation, operation and analysis of readings, the newly developed NivuFlow 750 flow meter, from Nivus GmbH (Germany), is moreover equipped with the communication functions required. Previous tests using the accompanying flow velocity sensor based on the ultrasonic cross correlation method were extremely successful. The operators hence decided to initiate test measurements in order to gather experience during operation.

The cross correlation method uses discrete velocities prevailing within a cross-section at the measurement place for flow measurement. These discrete velocities can be used to determine the entire flow profile. The profile then is used to accurately compute the flow rate.

In standard applications the cable lengths between sensor and transmitter rarely exceed 100 m. In Bouzey reservoir however cable lengths of up to 800 m are required. Due to installation within the dam body it is not possible to use wireless data transmission systems.

A new feature of the Multiplexer Module for NivuFlow 750 significantly extends the operational range of the transmitter. Specialised line driver functions now allow a total distance of 1.200 m between sensor and transmitter.

Thanks to using this module it was possible to install the transmitter out of the dam body without any problems. Since initial start the system operates smoothly. Once fully equipped, it will provide a comfortable and quick early warning system to reliably detect the first effects of possible structural damage. This is why disasters such as the breach in the dam in 1895 are now a thing of the past.


Digital Edition

AET 31.2 Buyers' Guide 2024

February 2024

In This Edition Buyer's Guide Directory - Product Listings by Category - Suppliers Listings (A-Z) Water / Wastewater - Methane Emissions Analysis at Berlin Wastewater Facility - Inter...

View all digital editions

Events

UzChemPlast Expo

Apr 03 2024 Tashkent, Uzbekistan

analytica 2024

Apr 09 2024 Munich, Germany

ChemBio Finland 2024

Apr 10 2024 Helsinki, Finland

View all events