• HY-OPTIMA™ 1700 Series Intrinsically Safe In-line Hydrogen Process Analyzer
    HY-OPTIMA™ 1700 Series Intrinsically Safe In-line Hydrogen Process Analyzer
  • HY-OPTIMA™ 1700 Series product family

Gas Detection

HY-OPTIMA™ 1700 Series Intrinsically Safe In-line Hydrogen Process Analyzer

Aug 10 2015

H2scan’s HY-OPTIMA™ 1700 series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 1700 series is an ATEX certified Intrinsically Safe (IS) device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 60°C. The HY-OPTIMA™ 1700 series is ideal for process gas applications where real time continuous measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.

You can download the HY-OPTIMA 1700 series data sheet by clicking here.
You can view the product webpage by clicking here.

Product Selections
The HY-OPTIMA™ 1700 Series product family includes sensor types that are designed for specific hydrogen ranges, corrosive gas tolerances and operation when no hydrogen is present. See the image below for more details.

1. 1720 products may be operated in an Air, O2 or N2 backgrounds (see manual). 
2. Sensor performance specifications assume a dry process stream, an ambient temperature of 25°C, pressure compensation and are in addition to any errors in the calibration gases used. The accuracy is specified for the serial port and digital display output only. 
3. Up to 10% H2S resistant product available with special conditioning charge on request.

* Sensor performance specifications are only valid for units configured for a maximum 65ºC dry process stream temperature. All figures assume pressure compensation, operating in ambient that do not contain Oxygen and are in addition to any errors in the gasses used. The accuracy is specified for serial port output only.

HY-OPTIMA™ is a registered Trademark of H2scan. Specifications subject to change without prior notice.


Digital Edition

IET 34.2 March 2024

April 2024

Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...

View all digital editions

Events

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

BWCE 2024

May 23 2024 Beijing, China

CEPE 2024

May 23 2024 Beijing, China

CISILE 2024

May 29 2024 Beijing, China

KIOSH

May 29 2024 Astana, Kazakhstan

View all events