Environmental Laboratory

Determination of Iopromide in Environmental Waters by Ion Chromatography-ICP-MS

Mar 14 2013

Author: Agilent Technologies on behalf of Agilent Technologies

Free to read

This article has been unlocked and is ready to read.

Download

Iopromide is an iodinated contrast medium (ICM), which is used to image internal body organs and blood vessels by x-ray or computerised tomography (CT) scan. Iopromide is generally given to patients in g/L concentrations and is excreted within 24 hours in the patient’s urine [1]. It is very hydrophilic (log Kow = –2.33) and non-ionic, properties that make it quite persistent in the environment. The molecular formula of iopromide is C18H24I3N3O8 and its chemical structure is shown in Figure 1.

Iopromide’s presence in surface waters and wastewaters has been widely reported as ranging from several ng/L to as much as 10 μg/L in sewage treatment plant effluents [2–4]. Furthermore, ICMs are known to be resistant to sewage treatment and studies have shown they are relatively poorly removed by conventional treatment processes [2, 5–7]. Due to its presence and environmental persistence, it has also been suggested that iopromide be used as a potential indicator compound of wastewater contamination [8].

Recent studies indicate that iopromide and other ICMs can form toxic iodinated disinfection bi-products (I-DBPs) during oxidation and disinfection water treatment processes [4, 9, 10]. Certain I-DBPs are known to be several times more toxic than chlorinated and brominated disinfection bi-products [11–13] but are, as yet, not regulated by the US Environmental Protection Agency (USEPA) or other regulatory agencies.

Most analytical methods developed for iopromide and other ICMs involve the use of LC coupled to a mass spectrometer, generally a triple quadrupole mass spectrometer [9, 14–17]. Hybrid methods involving ion trap and nuclear magnetic resonance have also been employed. This application note describes the optimised conditions for sensitive and reproducible analysis of sub-ppb levels of iopromide in water extracts, using an Agilent 1260 LC coupled to an Agilent 7700x ICP-MS. With the use of a 500 μL injection volume, we have established a lower method reporting limit (MRL) of 0.1 ppb for iopromide in the diluted methanol extracts in our assay; in theory this corresponds to a lower MRL of 2 ppt in our environmental water samples.

Experimental

Environmental water samples were collected at established monitoring points along the rivers and creeks in the state of California, including locations near water treatment plants. The water samples were filtered through 0.7 μm filters and then extracted using an automated solid-phase extraction (SPE) system. 200 mg hydrophilic-lipophilic balance (HLB) cartridges were first preconditioned with 5 mL of methyl tertiary butyl ether (MTBE), followed by 5 mL of methanol and 5 mL of HPLC grade water. 1 L of each sample was then loaded onto a cartridge at a fl ow rate of 15 mL/ min, after which the cartridges were rinsed with HPLC grade water followed by drying with nitrogen gas for 30 minutes. Adsorbed analytes were then eluted into 15 mL graduated conical tubes with 5 mL of methanol followed by 5 mL of 10/90 (v/v) methanol/MTBE solution. The eluent was then evaporated to a total volume less than 100 μL under flowing nitrogen followed by reconstitution to 1.0 mL total volume using methanol. 50 μL of this extract was then diluted with 950 μL of HPLC grade water to give the final extract used for IC-ICP-MS analysis.

These diluted extracts were injected into an Agilent 1260 HPLC coupled to an Agilent 7700x ICP-MS, with an injection volume of 500 μL. The chromatographic separation was performed using a Dionex AG16 4 x 50 mm guard column followed by a Dionex AS16 4 x 250 mm analytical column. A gradient elution from 2–90 mM sodium hydroxide (NaOH) was established, using a binary gradient consisting of reagent water (A) and 100 mM NaOH (B) with a constant flow rate of 1.0 mL/min. Gradient parameters were as follows: 2% B for 18.5 minutes then increased linearly for 3.5 minutes to 40% B and held for two minutes, finally stepping up to 90% B and holding for six minutes. The gradient returned to 2% B for five minutes at the end of the run, to re-equilibrate the column, giving a total run time of 35 minutes. A 25 second needle wash using 10% aqueous methanol was used following all injections of standards and samples.

The Agilent 7700x ICP-MS was operated with HMI sample introduction (0.6 L/min dilution gas, 0.5 L/min carrier gas, sample depth = 9 mm) and in helium collision mode (He flow 3.5 mL/min). Iodine (m/z 127) intensity was monitored in time-resolved analysis (TRA) mode using a 2 second integration time over a 37 minute time window. The use of HMI allows for extended analysis of high matrix samples with minimal matrix deposition in the interface cones, and the use of the He collision cell removes potential polyatomic interferences on masses 127 such as 126XeH+. A calibration curve for iopromide was prepared using aqueous standards with concentrations of 0.0, 0.1, 1, 10, 100 and 1000 ppb of intact compound (Figure 3).

Results and discussion

Using the method described, we have been able to detect iopromide in all non-zero standards used in our study. The chromatogram obtained for the 0.1 ppb injection is clearly distinguishable from the blank injection (Figure 2), and the calibration curve is linear over four orders of magnitude (Figure 3). This concentration range encompasses the levels at which iopromide has been observed in environmental waters including undiluted wastewater effluent.

The standards and samples in this report were analysed during a 24 hour continuous sequence. The results obtained from this sequence are shown in Table 1. The other CCVs analysed at the end of this sequence all agreed with their predicted values within approximately 10%.

In addition to iopromide, several other iodine containing compounds were detected in our chromatograms (Figure 4). These unknown species can be quantified based on their iodine content, using compound-independent calibrations (CIC), where the iodine content of an unknown compound is calibrated using the iodine response for a known compound, in this case iopromide. ICP-MS is ideally suited for analysis using CIC, as the high temperature ICP ion source ensures that the elemental response of the target element (iodine in this case) is essentially independent of the compound in which the target element is present. The quantitation of the iodine content in these unidentified peaks is listed in Table 2.

Conclusions

We have successfully quantified iopromide in a series of environmental water extracts using an Agilent 1260 LC coupled to an Agilent 7700x ICP-MS. This experimental arrangement allowed for us to establish an analytical method with a lower method reporting limit (MRL) of 0.1 ppb iopromide in extracts prepared via automated SPE. The use of the HMI interface allowed for an extended (>24 h) analysis to be completed (using non-volatile eluents) with minimal matrix deposition on the interface cones, and the use of He collision gas mode provides effective removal of polyatomic interferences. Not only does our work confirm and quantitate the presence of iopromide in these environmental samples, it indicates the presence of other iodinated organic compounds in these samples that are likely from anthropogenic sources and may prove to be biologically active.

References

1. Steger-Hartmann, T. et al. (2002). Investigations into the environmental fate and effects of iopromide (ultravist), a widely used iodinated x-ray contrast medium. Water Research, 36(1), 266–274.

2. Ternes, T. A. & Hirsch, R. (2000). Occurrence and behavior of x-ray contrast media in sewage facilities and the aquatic environment. Environmental Science & Technology, 34(13), 2741–2748.

3. Carballa, M., et al. (2004). Behavior of pharmaceuticals, cosmetics and hormones in a sewage treatment plant. Water Research, 38(12), 2918–2926.

4. Kormos, J. L., Schulz, M. & Ternes, T. A. (2011). Occurrence of iodinated x-ray contrast media and their biotransformation products in the urban water cycle. Environmental Science & Technology, 45(20), 8723–8732.

5. Drewes, J. E., Fox, P. & Jekel, M. (2001). Occurrence of iodinated x-ray contrast media in domestic effluents and their fate during indirect potable reuse. Journal of Environmental Science and Health Part A — Toxic/Hazardous Substances & Environmental Engineering, 36(9), 1633–1645.

6. Drewes, J. E., et al. (2003). Fate of pharmaceuticals during ground water recharge. Ground Water Monitoring and Remediation, 23(3), 64–72.

7. Snyder, S. A., et al. (2007). Role of membranes and activated carbon in the removal of endocrine disruptors and pharmaceuticals. Desalination, 202(1–3), 156–181.

8. Dickenson, E. R. V. et al. (2011). Indicator compounds for assessment of wastewater effl uent contributions to flow and water quality. Water Research, 45(3), 1199–1212.

9. Duirk, S. E., et al. (2011). Formation of toxic iodinated disinfection byproducts from compounds used in medical imaging. Environmental Science & Technology, 45(16), 6845–6854.

10. Schulz, M. et al. (2008). Transformation of the x-ray contrast medium iopromide in soil and biological wastewater treatment. Environmental Science & Technology, 42(19), 7207–7217.

11. Richardson, S. D. et al. (2008). Occurrence and mammalian cell toxicity of iodinated disinfection byproducts in drinking water. Environmental Science & Technology, 42(22), 8330–8338.

12. Richardson, S. D. et al. (2007). Occurrence, genotoxicity, and carcinogenicity of regulated and emerging disinfection byproducts in drinking water: A review and roadmap for research. Mutation Research-Reviews in Mutation Research, 636(1–3), 178–242.

13. Smith, E. M. et al. (2010). Comparison of byproduct formation in waters treated with chlorine and iodine: relevance to point-of-use treatment. Environmental Science & Technology, 44(22), 8446–8452.

14. Putschew, A., Schittko, S. & Jekel, M. (2001).

Quantification of triiodinated benzene derivatives and x-ray contrast media in water samples by liquid chromatography-electrospray tandem mass spectrometry. Journal of Chromatography A, 930(1–2), 127–134.

15. Hirsch, R. et al. (2000). A sensitive method for the determination of iodine containing diagnostic agents in aqueous matrices using LC-electrospray-tandem-MS detection. Fresenius Journal of Analytical Chemistry, 366(8), 835–841.

16. Ternes, T. A. (2001). Analytical methods for the determination of pharmaceuticals in aqueous environmental samples. Trac-Trends in Analytical Chemistry, 20(8), 419–434.

17. Vanderford, B. J. et al. (2011). Assessment of sample preservation techniques for pharmaceuticals, personal care products, and steroids in surface and drinking water. Analytical and Bioanalytical Chemistry, 399(6), 2227–2234.

 

Free to read

This article has been unlocked and is ready to read.

Download


Digital Edition

IET 34.2 March 2024

April 2024

Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...

View all digital editions

Events

Ozwater'23

Apr 30 2024 Melbourne, Australia

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

CleanPower 2024

May 06 2024 Minneapolis, MN, USA

View all events